ThermoCoolHubHVAC, refrigeration, cold chain, compressors, heat pumps, and ventilation equipment for global industrial buyers.
Insulated Ribbed Metal Panel - CF 7.2 Insul-Rib™ | Metl-Span
Cold Room Panels

Insulated Ribbed Metal Panel - CF 7.2 Insul-Rib™ | RFQ Sourcing Details

Cold Room Panels · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryCold Room Panels
Unitset
26/2624/26 22/26 26/24 24/24 22/24 26/22 24/22 22/22
ASTM C1363Thermal Performance of Building Materials and Envelope Assemblies See Thermal Performance Guide
ASTM E1592Structural Performance of Metal Roof and Siding Systems by Uniform Static Air Pressure Differences See load chart
Air InfiltrationASTM E283 Rate of Air Leakage Through Curtain Walls Under Specified Pressure Differences
Coverage WidthNominal 36″
FM 4880Class 1 Fire Rating of Insulated Wall, Ceiling and Roof Panels Product approved (Exterior wall requires FM 4881, see Structural approvals)
CategoryCold Room Panels
AvailabilityInquiry required
Source date2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Cold Room Panels. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Commercial & Industrial Products CF 7.2 Insul-Rib™ Wall Panel Home | Products | Wall | Insulated Metal Panels | CF 7.2 Insul-Rib™ Wall Panel Back to Previous Page Download as PDF CF 7.2 Insul-Rib™ Wall Panel CF 7.2 Insul-Rib™ insulated and ribbed metal wall panel combines a traditional 7.2 ribbed panel design with an insulated foam core.

Ideal for any commercial or industrial application, our panels provide the strength and durability of ribbed metal panels along with the thermal performance of an insulated metal panel. The 7.2 panel’s bold yet ribbed pattern compliments its unique industrial appearance.

Its distinctive exterior creates a shadow effect while adding texture, differentiating it from other panels. Since the panel is capable of being installed both vertically and horizontally, architects can be flexible when it comes to design.

Our panels are designed with the lock-and-groove system, allowing for an overall efficient installation, while simultaneously reducing construction labor costs. They are also capable of being combined with other CF joint profiles of the same thickness to create a visually appealing look.

Coverage Width Nominal 36″ Thermal Values – R-Value & U-Factor U-Factor(BTU/h-ft2*fahrenheit) Panel Width: 36″ 3″ = 0.066 4″ = 0.043 R-Value (h*ft2*F/BTU) Panel Width: 36″ 3″ = 15.2 4″ = 23.3 Exterior Face G-90 galvanized or AZ-50 aluminum-zinc coated steel in 26, 24 or 22** Ga.

Interior Face G-90 galvanized or AZ-50 aluminum-zinc coated steel in 26, 24 or 22 Ga.

Finishes Fluropon®, Fluropon® Premier, Fluropon® Classic, Flurothane®, Flurothane® Coastal, WeatherXL™, Igloo White Polyester Joint Offset double tongue-and-groove with extended metal shelf for positive face fastening, through fastening required at panel ends.

Length Non-Directional Embossed 8′-0″ to 32′-0″ Horizontal 8′-0″ to 40′-0″ Vertical Unembossed 8′-0″ to 32′-0″ Horizontal 8′-0″ to 40′-0″ Vertical Thickness 3″, 4″ (Rib height included in thickness) * Based on ASTM C518, ASTM C1363 and thermal modeling. Not available in unembossed.

*Through fastening required at panels ends. Ribbed portion of the panel is not included in R Values.

rofile with unique shadow effects Utilizes concealed clips and eliminates thermal short circuits Easy and fast installation, with reduced construction labor costs Can be used in conjunction with other Metl-Span CF joint profiles of the same thickness Color Offerings Explore Color Chart 1.

Metallic paint finishes will exhibit color shift, shade variances, striations and longitudinal patterning that are inherent characteristics and are not a product defect or cause for rejection. 2. All Metl-Span colors are formulated to provide maximum energy-efficiency and solar reflectivity.

All standard available Premium I and Premium II colors have been formulated for maximum solar reflectance. 3. Prices vary by color, gauge and quantity of metal. Please . 4.

All colors shown are approximate actual finish colors displayed as accura terature Product Showcase 7.2 Data Sheet with PUR V6-X Span Clip Metl-Span ® 7.2 Insul.

RibTM Wall Panel For Commercial & Industrial Buildings 2012 Master Format™ Section CF Wall Panels with PUR Guide Specifications US Document CF Wall Panels with PUR Guide Specifications US PDF All specifications and designs are subject to change without notice.

Load Span Tables The Load Span Tables below are based on Allowable Stress Design (ASD). For loads calculated based on ASCE 7-10 (LRFD), please refer to section 2.4.1 of ASCE 7-10 for the applicable load combinations using Allowable Stress Design.

For FM Global Requirements, click here 7.2 Insul-Rib™ Wall Panel Load Span Tables Panel Weights Panel Weights in Pounds Per Square Foot THICKNESS GAUGE (EXTERIOR FACE/INTERIOR FACE) 26/26 24/26 22/26 26/24 24/24 22/24 26/22 24/22 22/22 2.5″ ″ ″ ″ ″ Exterior Skin 22 gauge = 1.53 24 gauge = 1.26 26 gauge = .99 Interior Skin 22 gauge = 1.27 24 gauge = 1.04 26 gauge = 0.82 Foam Core 2.5″ = .37 3″ = .47 4″ = .68 5″ = .89 6″ = 1.1 Commercial & Industrial Panels – Horizontal 7.2-Rib Details 7.2H-BE-01: C&I Horizontal Flush Base Detail on Module w/ Extended Trim 7.2H-BE-02: C&I Horizontal Flush Base Detail w/ Drip Edge 7.2H-BE-03: C&I Horizontal Flush Base Detail on Module w/ Extrusion 7.2H-BE-04: C&I Horizontal Flush Base Detail w/ Extrusion 7.2H-CE-01: C&I Horizontal Outside Corner Detail 7.2H-CE-02: C&I Horizontal Inside Corner Detail 7.2H-HD-01: C&I Horizontal Window Header Detail on Module w/ Drip Edge 7.2H-HD-03: C&I On Module Head Detail w/ Extrusion 7.2H-HD-04: C&I Off Module Head Detail w/ Extrusion 7.2H-JD-01: C&I Horizontal Window Jamb Detail 7.2H-JD-02: C&I Jamb Detail w/ Spacer Trim 7.2H-JT-01: C&I Horizontal Joint Detail 7.2H-JT-02: C&I Joint End-Dam Detail 7.2H-SD-01: C&I Horizontal Window Sill Detail w/ Spacer 7.2H-SD-02: C&I Sill Detail with Trim 7.2H-VJ-01: C&I Joint Detail Commercial & Industrial Panels – Vertical 7.2 Insul-Rib Details 7.2-BE-01: C&I Vertical Flush Base Detail w/ Drip Edge 7.2-BE-02: C&I Vertical Notched Base Detail w/ Drip Edge 7.2-BE-03: C&I Vertical Flush Base Detail w/ Extended Trim Leg 7.2-BE-04: C&I Vertical Notched Base Detail w/ Extended Trim Leg 7.2-BE-05: C&I Vertical Overhang Base Detail w/ Drip Edge 7.2-CE-01: C&I Vertical Outside Corner Detail 7.2-CE-02: C&I Vertical Outside Corner Detail w/ Spacer Trim 7.2-CFR-01: C&I Vertical Wall to Gutter Detail w/ CFR42 Roof Panel 7.2-CFR-02: C&I Vertical Wall to Rake Detail w/ CFR42 Roof Panel 7.2-HD-01: C&I Vertical Door Header Detail w/ Drip Edge 7.2-JD-01: C&I Vertical Door Jamb Detail 7.2-JD-02: C&I Vertical Door Jamb Detail w/ Space Trim 7.2-JT-01: C&I Vertical Joint Detail 7.2-SD-01: C&I Vertical Window Sill Detail V6 X-Span Clip V6 X-Span Clip V6 X-Span Clip Promo V6 X-Span Edge Trim Commercial & Industrial Panels – Horizontal 7.2 Insul-Rib Horizontal Flush Base Detail w/ Lap Trim Flush Base Detail w/ Extrusion Off Module Flush Base Detail w/ Extrusion Off Module Head Detail w/ Extrusion On Module Head Detail w/ Trim On Module Head Detail w/ Extrusion Overhang Base Detail w/ Trim Outside Corner Detail w/ Trim Inside Corner Detail w/ Trim Jamb Detail w/ Trim Joint Detail Joint End-Dam Detail Sill Detail w/ Spacer Trim Sill Detail w/ Trim Commercial & Industrial Panels – Vertical 7.2 Insul-Rib Vertical Flush Base Detail W/ Drip Trim Notch Base Detail W/ Drip Trim Flush Base Detail W/ Lap Trim Notch Base Detail W/ Lap Trim Overhang Base Detail W/ Drip Trim Eve Detail w/ Northern Gutter Rake Detail Head Detail W/ Trim Jamb Detail w/ Trim Jamb Detail w/ Spacer Trim Joint Detail Sill Detail w/ Trim V6 X-Span Clip V6 X-Span Clip Book Lorem ipsum dolor sit amet, consectetur adipiscing elit.

Ut elit it it it it it

Insulated | Applications and Buyer Notes

Insulated is organized as a sourcing-ready Cold Room Panels reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questi

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Cold Room PanelsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
26/26
24/26 22/26 26/24 24/24 22/24 26/22 24/22 22/22Based on visible page data; confirm exact value in the RFQ.
ASTM C1363
Thermal Performance of Building Materials and Envelope Assemblies See Thermal PeBased on visible page data; confirm exact value in the RFQ.
ASTM E1592
Structural Performance of Metal Roof and Siding Systems by Uniform Static Air PrBased on visible page data; confirm exact value in the RFQ.
Air Infiltration
ASTM E283 Rate of Air Leakage Through Curtain Walls Under Specified Pressure DifBased on visible page data; confirm exact value in the RFQ.
Coverage Width
Nominal 36″Based on visible page data; confirm exact value in the RFQ.
FM 4880
Class 1 Fire Rating of Insulated Wall, Ceiling and Roof Panels Product approvedBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryCold Room Panels
Unitset
26/2624/26 22/26 26/24 24/24 22/24 26/22 24/22 22/22
ASTM C1363Thermal Performance of Building Materials and Envelope Assemblies See Thermal Performance Guide
ASTM E1592Structural Performance of Metal Roof and Siding Systems by Uniform Static Air Pressure Differences See load chart
Air InfiltrationASTM E283 Rate of Air Leakage Through Curtain Walls Under Specified Pressure Differences
Coverage WidthNominal 36″
FM 4880Class 1 Fire Rating of Insulated Wall, Ceiling and Roof Panels Product approved (Exterior wall requires FM 4881, see Structural approvals)
FM 4881Class 1 Exterior Wall Structural Performance See FM Global Requirements (Interior wall requires FM 4880, see Fire approvals)
FinishesFluropon®, Fluropon® Premier, Fluropon® Classic, Flurothane®, Flurothane® Coastal, WeatherXL™, Igloo White Polyester
Fire USASTM E84 Surface Burning Characteristics of Building Materials Flame spread
JointOffset double tongue-and-groove with extended metal shelf for positive face fastening, through fastening required at panel ends.
LengthNon-Directional Embossed 8′-0″ to 32′-0″ Horizontal 8′-0″ to 40′-0″ Vertical Unembossed 8′-0″ to 32′-0″ Horizontal 8′-0″ to 40′-0″ Vertical
NFPA 285-19Evaluation of Fire Propagation Characteristics of Exterior Non-Load Bearing Wall Assemblies Panel assembly met the requirements of the standard
Special ApprovalState of Florida Product Approval for the State of Florida Product has State of Florida approval
THICKNESSGAUGE (EXTERIOR FACE/INTERIOR FACE)
Test/ApprovalTest Method Test Title Results
Thermal Values – R-Value & U-FactorU-Factor-ft2*fahrenheit) Panel Width: 36″ 3″ = 0.066 4″ = 0.043 R-Value
Water InfiltrationASTM E331 Water Penetration of Exterior Walls by Uniform Static Air Pressure Differences No uncontrolled leakage when tested to a static pressure of 20 psf Vertical or horizontal installation

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

ThermoCoolHub related sourcing paths

Related categories ThermoCoolHub related paths

Cold Room Equipment

Commercial Refrigeration

HVAC Units and Heat Pumps

Related applications ThermoCoolHub related paths

Commercial Building HVAC

Cold Chain Storage

Related solutions ThermoCoolHub related paths

Cold Room Equipment Sourcing

ThermoCoolHub procurement phrases

ThermoCoolHub related product samples

Supplier profile

ThermoCoolHub Imported Supplier Pool
主营:Cold Room Panels

View full profile >