Product specs

CategoryCommercial Refrigeration
Unitset
ESPPa
TypeChiller
UsageCommercial/Industrial
Method/ Flare Flare Flare Welding Welding Welding
OriginChina
Airflowm 3 /h
CategoryCommercial Refrigeration
AvailabilityInquiry required
Source date2026-05-30

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Commercial Refrigeration. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. . Model NO. AA20-104 Corrosion Durability General Operating Voltage 380-415, 440, 460, 50/60.

Hz Noise Level Ordinary Application Fields Supermarket, Hospital, Pharmaceutical and Building Mounting Split Lifetime 15~20 years Certification ISO, CE Condition New Usage Commercial/Industrial Cooling Cooling Only or Heat Pump Refrigerant R22/R407c/R410A/R134A Filter Type Pre, Medium and HEPA(Optional) Transport Package Standard Package Fit for Transportation Specification Color: white Trademark AMRTA or OEM Origin China HS Code Production Capacity 10000PCS/Year Packaging & Delivery Package Size 1020.00cm * 1030.00cm * 830.00cm Package Gross Weight 170.000kg 20-104kw Commercial Condensing unit Cooling Machine 11 sizes available ranging from 19.5 kW to 103.7 kW cooling capacity.

Cooling only and heat pump version. Wide application as ho rotected with polyester powder painting to ensure total resistance to atmospheric agents. High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.

Compact indoor design, long air supply distance. Outdoor units are equipped with low noise axial fans. Indoor units are equipped with quiet centrifugal fans. Split installation, connected by means of flare/welding coupling.

Easy operation line controller: Cooling/Heating/Fan/Auto Timing On/Off Error indication Multi safety protection High/low pressure protection Time delay and antifreeze switch Phase sequence relay Current overload protection Overheat protection OPTIONAL Additional electric heater on indoor unit Additional heating coil on indoor unit TECHNICAL DATA Mod.

Nominal cooling capacity* kW Nominal heating capacity* * kW Connection Method / Flare Flare Flare Welding Welding Welding Liquid pipe diameter ¢mm 9.52x2 12.7x2 12.7x2 15.88x1 15.88/ /12.7 Gas pipe diameter ¢mm 15.88x2 19.05x2 19.05x2 28x1 28/19.05 28/19.05 Power supply / 230V/3N/60.

Hz OUTDOOR UNIT Compressor Qty/refrigerant circuit Nr. 2/2 2/2 2/2 1/1 2/2 2/2 Cooling power input* kW Heating power input kW Energy adjustment % Axial fans Quantity Nr. Airflow m 3 /h Sound pressure level * dB(A) Net weight kg INDOOR UNIT Centrifugal fans Quantity Nr.

Airflow m 3 /h ESP Pa Sound pressure level * dB(A) Net weight kg Additional electric heater kW 2×3 2×4 2×5 2×6 2×6 2×8 Additional heating coil ** kW Mod Nominal cooling capacity* kW Nominal heating capacity* * kW Connection Method / Welding Welding Welding Welding Welding Liquid pipe diameter ¢mm 15.88/ ×2 15.88×2 15.88×2 19.05×2 Gas pipe diameter ¢mm 28/19.05 28×2 28×2 28×2 35×2 Power supply / 230V/3N/60.

Hz OUTDOOR UNIT Compressor Qty/refrigerant circuit Nr. 2/2 2/2 2/2 2/2 2/2 Cooling power input* kW Heating power input kW Energy adjustment % Axial fans Quantity Nr. Airflow m 3 /h Sound pressure level * dB(A) Net weight kg INDOOR UNIT Centrifugal fans Quantity Nr.

Airflow m 3 /h ESP Pa Sound pressure level * dB(A) Net weight kg Additional electric heater kW 2×8 2×10 2×10 2×12 2×14 Additional heating coil ** kW Performance values refer to the following conditions: * Cooling capacity is measured under the condition: indoor temperature DB 27°C/ WB 19°C, ambient temperature DB 35°C / WB 24°C.

** Heating capacity is measured under the condition: indoor temperature DB 20°C / WB 15°C, ambient temperature DB 7ºC / WB 6°C. * Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field. ** Optional as request.

Unit Pictures Some Overseas Simple Projects Our Products Range Jinan Amrta Air Conditioning Co., Ltd.

High | Applications and Buyer Notes

High is organized as a sourcing-ready Commercial Refrigeration reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time que

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Commercial RefrigerationBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
ESP
PaBased on visible page data; confirm exact value in the RFQ.
Type
ChillerBased on visible page data; confirm exact value in the RFQ.
Usage
Commercial/IndustrialBased on visible page data; confirm exact value in the RFQ.
Method
/ Flare Flare Flare Welding Welding WeldingBased on visible page data; confirm exact value in the RFQ.
Origin
ChinaBased on visible page data; confirm exact value in the RFQ.
Airflow
m 3 /hBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryCommercial Refrigeration
Unitset
ESPPa
TypeChiller
UsageCommercial/Industrial
Method/ Flare Flare Flare Welding Welding Welding
OriginChina
Airflowm 3 /h
CoolingCooling Only or Heat Pump
Voltage380-415, 440, 460, 50/60Hz Noise Level Ordinary
Lifetime15~20 years
MountingSplit
QuantityNr.
diameter¢mm 28/19.05 28×2 28×2 28×2 35×2
ConditionNew
Model NO.AA20-104
TrademarkAMRTA or OEM
Net weightkg
ApplicationFields Supermarket, Hospital, Pharmaceutical and Building Mounting Split Lifetime 15~20 years
Filter TypePre, Medium and HEPA(Optional)
INDOOR UNITCentrifugal fans
Noise LevelOrdinary
RefrigerantR22/R407c/R410A/R134A
OUTDOOR UNITCompressor
Package Size1020.00cm * 1030.00cm * 830.00cm
Power supply/ 230V/3N/60Hz
CertificationISO, CE
CustomizationAvailable
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Shipping Cost.
SpecificationColor: white
Air Tube MaterialGalvanized Sheet
Energy adjustment%
Gas pipe diameter¢mm 15.88x2 19.05x2 19.05x2 28x1 28/19.05 28/19.05
Operating Voltage380-415, 440, 460, 50/60Hz
Transport PackageStandard Package Fit for Transportation
Application FieldsSupermarket, Hospital, Pharmaceutical and Building
Production Capacity10000PCS/Year
Cooling power input*kW
Corrosion DurabilityGeneral
Liquid pipe diameter¢mm 9.52x2 12.7x2 12.7x2 15.88x1 15.88/ /12.7
Package Gross Weight170.000kg
Heating power input**kW
US$1, ,988.001 Piece ( )
Qty/refrigerant circuitNr. 2/2 2/2 2/2 1/1 2/2 2/2
Sound pressure level ***dB(A)
Nominal cooling capacity*kW
Nominal heating capacity* *kW
Additional heating coil ****kW
Additional electric heater ****kW 2×3 2×4 2×5 2×6 2×6 2×8

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

ThermoCoolHub related sourcing paths

Related applications ThermoCoolHub related paths

Commercial Building HVAC

Food Refrigeration Projects

Related solutions ThermoCoolHub related paths

HVAC Project Procurement

Refrigeration Parts Replacement

ThermoCoolHub procurement phrases

ThermoCoolHub related product samples