Product specs

CategoryCommercial Refrigeration
Unitset
ModelJZF04D-U
Power3.92 (unit not stated)
Voltage380 V
MaterialSteel
CondenserU-45
ConditionNew
CategoryCommercial Refrigeration
AvailabilityInquiry required
Source date2026-07-24

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Commercial Refrigeration. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The JZF04D-U is a new, air-cooled condensing unit intended for commercial refrigeration systems. The listed configuration uses a semi-hermetic compressor and a horizontal steel structure.

Its documented components include a 4EES-4Y compressor model, U-45 condenser, one 450 mm fan blade, a 250 W fan motor, pressure gauges, refrigeration piping, and a liquid receiver.

Published operating data lists refrigeration capacity at 5,410 W, power at 3.92, total air volume at 4,711, a 380 V electrical supply, four motor poles, and a 12 mm outlet pipe. The product information lists R404A, R507A, R4484A, R449A, and R410A among the refrigerant options.

CCC certification is stated, and the unit can be supplied in a wooden case or carton. Customization and customized logo marking are available. Supported facts should be distinguished from project-specific suitability.

Buyers should confirm the exact refrigerant charge and configuration, operating temperatures, ambient design conditions, electrical frequency and phase, capacity test conditions, compressor displacement, connection sizes, controls, protection devices, noise level, overall dimensions, net weight, and included accessories before ordering.

The stated value “3.92” should also be confirmed for its unit of measurement. Compatibility with the intended cold room, cabinet, evaporator, piping layout, and local installation requirements should be reviewed by the buyer’s refrigeration engineer.

Buyers should additionally confirm the final production specification, inspection documentation, packaging details, commissioning requirements, spare-parts scope, warranty, and commercial terms.

JZF04D-U | Applications and Buyer Notes

JZF04D-U is organized as a sourcing-ready Commercial Refrigeration reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Commercial RefrigerationBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
JZF04D-UBased on visible page data; confirm exact value in the RFQ.
Power
3.92 (unit not stated)Based on visible page data; confirm exact value in the RFQ.
Voltage
380 VBased on visible page data; confirm exact value in the RFQ.
Material
SteelBased on visible page data; confirm exact value in the RFQ.
Condenser
U-45Based on visible page data; confirm exact value in the RFQ.
Condition
NewBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryCommercial Refrigeration
Unitset
ModelJZF04D-U
Power3.92 (unit not stated)
Voltage380 V
MaterialSteel
CondenserU-45
ConditionNew
Fan blade1 × 450 mm
Motor poles4
Outlet pipe12 mm
CertificationCCC
Fan motor power250 W
Structural formHorizontal
Compressor model4EES-4Y
Total air volume4,711 (unit not stated)
Refrigerant optionsR404A, R507A, R4484A, R449A, R410A, and additional options
Refrigeration capacity5,410 W

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

ThermoCoolHub related sourcing paths

ThermoCoolHub procurement phrases

ThermoCoolHub related product samples

Supplier profile

ThermoCoolHub Imported Supplier Pool
主营:Commercial Refrigeration

View full profile >