ThermoCoolHubHVAC, refrigeration, cold chain, compressors, heat pumps, and ventilation equipment for global industrial buyers.
Solar Energy Electric Water Heater 50-500 Liters Heat Pump Buffer Tank
Air Handling Units

Solar Energy Electric Water Heater 50-500 Liters | RFQ Sourcing Details

Air Handling Units · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryAir Handling Units
Unitset
CategoryAir Handling Units
AvailabilityInquiry required
Source date2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Air Handling Units. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Custom Capacity Air Source All in One Air to Water Heat Pump Hot Water Heater Tank Buffer Tank Features: • As simple as installing an air conditioner;• The product is suitable for independent systems such as high-rise buildings and families;• Not affected by climate, weather, building conditions, etc.;• Adopt diamond armor to thicken the inner tank and imported enamel glaze, which is anti-explosion, anti-solvent, acid and alkali resistance, and has a long service life;• Select high-efficiency outer plate heat exchange structure, solve problems such as corrosion and water leakage, and make the operation of the unit more stable;• Auxiliary electric heating can also be used for heating in severe cold areas.

Product Parameters Model PF-100L PW-200L/coil PF-200L PW-300L PF-300L PW-500L PF-500L Type Buffer Tank Water Tank Buffer Tank Water Tank Buffer Tank Water Tank Buffer Tank Volume/Liter Inner tank Materials SUS304 SUS304 SUS304 SUS304 SUS304 SUS304 SUS304 Inner tank thickness/mm Housing materials Color steel plate Color steel plate Color steel plate Color steel plate Color steel plate Color steel plate Color steel plate Housing thickness Coil materials / SUS304 / SUS304 / SUS304 / Coil type / Corrugated Pipe / Corrugated Pipe / Corrugated Pipe / Coil size / φ25mm*20m / φ32mm*25m / φ32mm*20m/φ32mm*20m / Coil thickness/mm / 0.3 / 0.3 / 0.3 / Coil area/m / 2.2 / 3.5 / 2.8/2.8 / Cold Water Inlet / G3/4" M / G3/4" M / G1" F / Hot Water Outlet / G3/4" M / G3/4" M / G1" F / Circulation inlet 1 G1" F G1" M G5/4" F G5/4" F G5/4" F G5/4" M G5/4" F Circulation outlet 1 G1" F G1" M G5/4" F G5/4" F G5/4" F G5/4" M G5/4" F Circulation inlet 2 G1" F / G5/4" F / G5/4" F G5/4" M G5/4" F Circulation outlet 2 G1" F / G5/4" F / G5/4" F G5/4" M G5/4" F Water return hole / G3/4" F / G3/4" F / / / Water filling hole G3/4" F / G3/4" F / G3/4" F / G3/4" F Exhaust vent G1/2" F / G1/2" F / G3/4" F / G3/4" F Electric heater hole G1" F G1" F G1" F G1" F G1" F G1" F / Electric heater 3kW 3kW 3kW 3kW 3kW 3kW / Electric heater controller / / / / / / / Temperature sensor G3/8" F G3/8" F G3/8" F G3/8" F G3/8" F G3/8" F G3/8" F Magnesium rod hole / G3/4" F / G3/4" F / G3/4" F / P/TP valve hole / G3/4" F / G3/4" F / G3/4" F / Safe valve hole G1/2" F / G1/2" F / G1/2" F / G1/2" F Sewage o

Solar | Applications and Buyer Notes

Solar is organized as a sourcing-ready Air Handling Units reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time question

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Air Handling UnitsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryAir Handling Units
Unitset

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

ThermoCoolHub related sourcing paths

Related categories ThermoCoolHub related paths

HVAC Units and Heat Pumps

Air Source Heat Pumps

Ventilation and Air Treatment

Related applications ThermoCoolHub related paths

Cold Chain Storage

Commercial Building HVAC

Related solutions ThermoCoolHub related paths

Cold Room Equipment Sourcing

ThermoCoolHub procurement phrases

ThermoCoolHub related product samples