ThermoCoolHubHVAC, refrigeration, cold chain, compressors, heat pumps, and ventilation equipment for global industrial buyers.
Dw-86L30 -86 Degree Ultra Low Temperature Medical Freezer
Air Source Heat Pumps

Dw-86L30 -86 Degree Ultra Low Temperature Medical | RFQ Sourcing Details

Air Source Heat Pumps · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryAir Source Heat Pumps
Unitset
CategoryAir Source Heat Pumps
AvailabilityInquiry required
Source date2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Air Source Heat Pumps. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Product Specification Deep freezer 30L -86 Degree Ultra Low Temperature Medical Freezer DW-86L30 Technical Advantage Unique single-stage refrigeration technology & design, strong cooling and quick freezing;With CFC free mixed refrigerants and foaming agent, high efficiency and energy saving;Components: World famous brand SECOP & Embraco compressor, strong cooling ,reliable and long working life;Famous brand controller: Italian Dixell/KELD temperature controller, high accuracy and with Hi/Low temperature & Sensor fault alarm;EBM Fan motor is reliable and long working life;SUS 304 stainless steel inner, healthy,durable and easy to clean;Thicker insulation and double door gaskets design proving enough energy saving;Full copper tube evaporator is durable and avoiding the inner leakage;Applications: The freezer equipment is used for low temperature storage of biological samples, organ specimens, relative materials and reagents at laboratory,Also for low temperature test of electronic component and chemical materials in Industrial sectors;Some also used for low temperature storage of deep seafood such as tuna fish, swordfish, sea fishing, etc.

Model DW-86L30 DW-86L50 DW-86L80 DW-86L158 DW-86L328 DW-86L400 Capacity 30 L 50 L 80 L 158 L 328 L 400 L Type Vertical Vertical Vertical Vertical Vertical Vertical Power supply 220V/50. Hz, 110V/60. Hz 220V/50. Hz, 110V/60. Hz 220V/50. Hz, 110V/60. Hz 220V/50. Hz, 110V/60. Hz 220V/50. Hz, 110V/60. Hz 220V/50.

Hz, 110V/60.

Hz Isolation thickness 120mm 120mm 120mm 120mm 130mm 130mm Temperature Range -40ºC~-86ºC -40ºC~-86ºC -40ºC~-86ºC -40ºC~-86ºC -40ºC~-86ºC '-40ºC~-86ºC Electronic controller with temperature display DIXELL DIXELL DIXELL DIXELL DIXELL DIXELL Condenser Copper fin type/Fan cooling Copper fin type/Fan cooling Copper fin type/Fan cooling Copper fin type/Fan cooling Copper fin type/Fan cooling Copper fin type/Fan cooling Evaporator All copper tube All copper tube All copper tube All copper tube All copper tube All copper tube Inside liner Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Inside door Yes Yes Yes Yes Yes Yes Lock & Key Optional Optional Optional Optional Optional Optional Rated input power 280W 300W 450W 500W 550W 800W Power consumption 3.8kwh/24h 4.2kwh/24h 4.8kwh/24h 5.4kwh/24h 6.5kwh/24h 9.2kwh/24h Refrigerant CFC Free(Mixed Gas) CFC Free(Mixed Gas) CFC Free(Mixed Ga

Dw-86L30 | Applications and Buyer Notes

Dw-86L30 is organized as a sourcing-ready Air Source Heat Pumps reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time qu

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Air Source Heat PumpsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryAir Source Heat Pumps
Unitset

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

ThermoCoolHub related sourcing paths

Related categories ThermoCoolHub related paths

Air Source Heat Pumps

HVAC Units and Heat Pumps

Ventilation and Air Treatment

Related applications ThermoCoolHub related paths

Food Refrigeration Projects

Cold Chain Storage

Related solutions ThermoCoolHub related paths

Cold Room Equipment Sourcing

Refrigeration Parts Replacement

ThermoCoolHub procurement phrases

ThermoCoolHub related product samples