ThermoCoolHubHVAC, refrigeration, cold chain, compressors, heat pumps, and ventilation equipment for global industrial buyers.
Ec Fan AC Fan Adiabatic Cooler with Wet Curtain for Gas Cooling
Controls Sensors And Installation Parts

Ec Fan AC Fan Adiabatic Cooler with Wet Curtain f | RFQ Sourcing Details

Controls Sensors And Installation Parts · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryControls Sensors and Installation Parts
Unitset
TypeAir-Cooled
FluidWater
ModelGjp12*3 Structure
LouverOutley
OriginChina
DiameterDN100 Outlet Tube DN100 Tube
CategoryControls Sensors And Installation Parts
AvailabilityInquiry required
Updated2026-06-02

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Controls Sensors And Installation Parts. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Adiabatic cooler /Dry coolers Dry coolers are utilized for the cooling of processing liquids, generally pure or brine water, particularly in refrigeration applications, air-conditioning, or industrial processes such as free-cooling and the cooling of liquids that circulate inside industrial moulding dies.

The coolers are so called "dry" since they utilize air as a secondary fluid. Compared to solutions that function with water, such as cooling towers, air avoids the problems resulting from the formation of incrustations.

Super Power-J Dry Coolers Super Power- Dry Coolers Performance range: Capacity from 290 to 2219 kW (ethylene glycol 35%, Tw1=40°C, Tw2=35°C, T1=25°C) Fans: Diameter Ø 800, 900, 1000 mm, AC or EC motor Benefits: Maximum performance, minimum footprint High efficiency geometry Modular design, 8-20 fans 8 sound levels Piping in copper or stainless steel AISI 304 or AISI 316L Finned pack available in a wide range of materials Complete range of accessories AFS (Air Fresh System).

Software calculation : The peculiar V-shaped structure of HACST Gas Cooler allows to make the most out of the adiabatic system and reduce the overall dimensions of the installation.

These units with the option of adiabatic air cooling allow an efficient operation even in regions where the ambient temperature could exceed 40 ° C, reducing the blocking chance of the refrigeration systems, commercial refrigeration (supermarkets) and industrial refrigeration (production, packaging and distribution).

The control panel developed for the management of the adiabatic system continuously adjusts the flow rate and consequently minimizes the water consumption based on the load request of the heat exchanger, the adjustment is based on the working speed of the electronically commutated motor fans, the factory parameters can be modified to adapt to different operating conditions and system needs (water saving / energy saving).

The cleaning system is available on request on all V-type units: a specific piping with two ramps per row with specific nozzles to wash the heat exchanger under pressure. The system allows the washing of the dirt accumulated on the finned pack from the inside towards the outside of the finned pack.

Product Parameters APPLICATIONS The V-shaped structure allows to reduce the installation dimensions. The Evaporative panel system increases capacity and efficiency of transcritical CO2 systems. Adiabatic cooling for an effective operation also in regions with high ambient temperatures.

Management of the adiabatic system to minimize water consumption.

High efficiency geometry Piping in copper or stainless steel AISI 304 or AISI 316L Finned pack available in a wide range of materials Complete range of accessories Casing in galvanized steel, powder painted CAPACITY [KW] 10 … 3000 FAN QUANTITY 1 … 20 FAN MOTORS AC/EC EVAPORATIVE PRE-COOLING AVAILABLE ADIABATIC SPRAY SYSTEM AVAILABLE LOW-NOISE MODELS AVAILABLE HEAT EXCHANGERS RTPF PROTECTIVE COATINGS AVAILABLE REFRIGERANTS WATER/BRINE WARRANTY 32YEARS Packing &Delivery

Ec | Applications and Buyer Notes

Ec is organized as a sourcing-ready Controls Sensors And Installation Parts reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Controls Sensors and Installation PartsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Type
Air-CooledBased on visible page data; confirm exact value in the RFQ.
Fluid
WaterBased on visible page data; confirm exact value in the RFQ.
Model
Gjp12*3 StructureBased on visible page data; confirm exact value in the RFQ.
Louver
OutleyBased on visible page data; confirm exact value in the RFQ.
Origin
ChinaBased on visible page data; confirm exact value in the RFQ.
Diameter
DN100 Outlet Tube DN100 TubeBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryControls Sensors and Installation Parts
Unitset
TypeAir-Cooled
FluidWater
ModelGjp12*3 Structure
LouverOutley
OriginChina
DiameterDN100 Outlet Tube DN100 Tube
MaterialAluminium Fan Protection IP65 Louver Outley Bare Tube 25*2.5
WARRANTY32YEARS
Bare Tube25*2.5
ConditionNew
Flow Rate2600ton/H
FrequencyFan Noise Level Ultra Low
Model NO.hacst
TrademarkHACST
FAN MOTORSAC/EC
ApplicationFields Chemical
Noise LevelUltra Low
Outlet TubeDN100
System TypeClosed System
Dirty Factor0.0002
FAN QUANTITY1 … 20
Fans SpeciesFrequency Fan
Fin MaterialAluminium
Package Size5500.00cm * 2200.00cm * 2250.00cm
REFRIGERANTSWATER/BRINE
CAPACITY [KW]10 … 3000
CertificationRoHS, UR, ISO, CE, CCC, CTI
Cooling WaterIndustrial Water
CustomizationAvailable
Specification60cbm/h
Tube MaterialCooper
Fan ProtectionIP65
HEAT EXCHANGERSRTPF
Structure ModelGjp12*3
LOW-NOISE MODELSAVAILABLE
Transport PackageContainer
Application FieldsChemical
Operation Pressure2.5bar
Structure MaterialGalvanized Steel
Inlet Tube DiameterDN100
PROTECTIVE COATINGSAVAILABLE
Production Capacity5000set/Year
ADIABATIC SPRAY SYSTEMAVAILABLE
EVAPORATIVE PRE-COOLINGAVAILABLE

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

ThermoCoolHub related sourcing paths

Related applications ThermoCoolHub related paths

Commercial Building HVAC

Food Refrigeration Projects

Related solutions ThermoCoolHub related paths

Refrigeration Parts Replacement

ThermoCoolHub procurement phrases

ThermoCoolHub related product samples